$32.41 + VAT
HM-PSE-S2 Morley Smoke Detector
SKU: HM-PSE-S2-
Humidity 10-93 % Diameter 102 mm Color White Material ABS Height 52 mm Weight 97 g
$32.41 + VAT
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
SKU: MI-PSE-S2-IV- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
$32.42 + VAT
HM-RHSE Honeywell Addressable Heat Detector Hna-360-H2
SKU: HM-RHSE-
Model HNA-360-H2 detector is advanced photoelectric smoke detection which is made with an innovative and modern design, every unit is individually tested and calibrated to ensure high reliability and prevent false alarms.
Compatible with: C-TEC, KENTEC, INIM, GLOBAL FIRE and other intelligent fire control panels.
$41.68 + VAT
MI-BSO-DD-N KAC Intelligent Detector Base Sounder Strobe
SKU: MI-BSO-DD-N-
The EN54-23 Detector Base Sounder Strobe is a modular, high output loop powered device intended to alert building occupants of a potential fire.
Approved to meet EN54-23, it utilizes the System Sensor B501AP base for enhanced installation flexibility and integrates seamlessly with System Sensor intelligent detectors into a single installation point.
When triggered by the fire panel, its powerful sounder and strobe provide an audible visible warning.
$43.98 + VAT
MI-DMMI Morley Interface – Single Input Monitor Module
SKU: MI-DMMI- Manufacturer : Morley by Honeywell
- Part Number : MI-DMMI
- Single Input Interface Module
- Requires M200E-SMB For Surface Mounting
$45.84 + VAT
MI-WSO-PR-N Morley IAS Wall Mounted Sounder – Addressable – Red
SKU: MI-WSO-PR-N- Manufacturer : Morley IAS by Honeywell
- Part Number : MI-WSO-PR-N
- Wall Mounted Addressable Sounder
- Colour : Red
- Requires B501AP Terminal Plate For Mounting
$48.16 + VAT
MI-MCP-FLEX Morley IAS Addressable Flexible Manual Call Point
SKU: MI-MCP-FLEXKey Features:
- Unique ‘Plug & Play’ installation concept
- Re-settable operating element option
- Analogue addressable communications
- Fully compliant with EN54, Part 11
- Backward compatibility
- Enhanced aesthetics
- Integral LED
- Integral loop isolation option
$50.93 + VAT
MI-DMM21 Morley 2-Input Monitor Module
SKU: MI-DMM21Fire detection and fire alarm systems installed in and around buildings
$74.08 + VAT
BEAMMMK System Sensor Mounting Kit
SKU: BEAMMMK- The BEAMMMK allows reflected beam detectors and reflectors to be mounted to either a vertical wall or the ceiling. The kit allows for additional alignment range in cases where the detector and reflector cannot be mounted within 10 degree of each other. The kit includes the hardware necessary to mount either a single transmitter/receiver unit or a single reflector. (To mount the transmitter/ receiver the surface mount kit, BEAMSMK, must also be used). If the transmitter/receiver and the reflector require additional alignment range two kits are required.
$78.71 + VAT
MI-D240CM0 Morley Single 240 V Ac Relay Module
SKU: MI-D240CM0The MI/D240CMO addressable output module provides a single double pole contact output for 240 V AC (nominal 220 V AC) to switches the power to external equipment. The MI/D240CMO has built-in lop short circuit isolator and surface box for wall mount.
$89.82 + VAT
MI-WSS-PR-N Morley Intelligent Wall Mounted Sounder Strobe
SKU: WSS-PR-N05
Features |
|
| Model : | WSS-PR-N05 |
| Type : | Intelligent Wall Mounted Sounder Strobe |
| Mounting Type : | Wall |
| Voltage : | 15 – 32V DC |
| Color : | Red |
$92.60 + VAT
MI-DCZRM Morley Non-Addressable Zone Monitor Module
SKU: MI-DCZRM- Connection of a zone of non-addressable detectors to an analogue addressable fire system
- Built in isolation allowing system installation in stages without loss of protection
- Monitors open circuit and short circuit faults
- TRI-Colour Status LED
- Zone powered from addressable loop wiring or external 24V PSU
- Remote reset of non-addressable zone
- Monitoring of external power supply
- External fault input
- CPD approval to EN54-17 and EN54-18, LPCB and VdS
- DIN rail mountable, consistent with all other modules
- Support for an extended power supply range as low as 18Vdc 60mA with an External PSU
$108.34 + VAT
CO1224TR System Sensor Carbon Monoxide Detector
SKU: CO1224TR- A 10-year end-of-life timer
- RealTest® enables a functional test using canned CO
- A code-required trouble relay
- Wiring supervision with SEMS terminals
- 12/24 VDC
- A low current draw of 20 mA in standby and 40 mA in alarm
- Versatile mounting for wall and ceiling
- Accurate and reliable electrochemical sensing technology
- Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T or CO1224A.
- CO1224T tested up to 12,000 feet above sea level
$129.64 + VAT
W5A-RPO5SF-K013 Morley IAS Addressable Glass Weatherproof Call Point
SKU: W5A-RPO5SF-K013Addressable call point for the Morley IAS protocol features Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the new WCP Outdoor Call Point range.
$132.41 + VAT
System Sensor D2 Duct Smoke Detector, 2-WIRe, Photoelectric
SKU: D2- Photoelectric, integrated low-flow technology
- Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
- Versatile mounting options in square or rectangular configuration with modular construction
- Plug-in sensor
- Superb false immunity with the latest sensor technology
- Broader ranges for operating temperature (-4ºF to 158ºF) and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- A cover tamperture to indicate a trouble condition for removed or improperly installed sensor cover
- Increased wiring space with a newly added 3/4 inch conduit knockout
- Improved LED status
- 24 V DC
- Backward compatibility with existing Innovair products, inclremote accessories
$138.89 + VAT
System Sensor Dnre Smoke Detector
SKU: DNRE- Photoelectric, integrated low-flow technology
- Air velocity rating from 0.5m/s to 20.32m/sec
- Versatile mounting options: square or rectangular configuration
- Broad ranges for operating temperature −20°C to 70°C and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- New Cover tamper signal
- Increased wiring space with a newly added 20mm conduit knockout
- Available space within housing to accommodate mounting of relay module
- Clear cover for convenient visual inspection
$166.68 + VAT
795-072-100 Morley Loop Driver Card For Morley IAS Protocol
SKU: 795-072-100-
Morley IAS Protocol Loop driver card for 460mA for ZX addressable fire alarm control panels.
$185.19 + VAT
FP200 Prysmian FIRe Resistant Cable
SKU: FP200-
FP200 Gold is a ‘standard’ fire resistant cable as defined by fire alarm and emergency lighting British Standards and the original alternative to mineral insulated cable. It is a tough, durable and dressable essential systems cable – easy to install and terminate.

HM-PSE-S2 Morley Smoke Detector
-
Humidity 10-93 % Diameter 102 mm Color White Material ABS Height 52 mm Weight 97 g

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base

HM-RHSE Honeywell Addressable Heat Detector Hna-360-H2
-
Model HNA-360-H2 detector is advanced photoelectric smoke detection which is made with an innovative and modern design, every unit is individually tested and calibrated to ensure high reliability and prevent false alarms.
Compatible with: C-TEC, KENTEC, INIM, GLOBAL FIRE and other intelligent fire control panels.

MI-BSO-DD-N KAC Intelligent Detector Base Sounder Strobe
-
The EN54-23 Detector Base Sounder Strobe is a modular, high output loop powered device intended to alert building occupants of a potential fire.
Approved to meet EN54-23, it utilizes the System Sensor B501AP base for enhanced installation flexibility and integrates seamlessly with System Sensor intelligent detectors into a single installation point.
When triggered by the fire panel, its powerful sounder and strobe provide an audible visible warning.

MI-DMMI Morley Interface – Single Input Monitor Module
- Manufacturer : Morley by Honeywell
- Part Number : MI-DMMI
- Single Input Interface Module
- Requires M200E-SMB For Surface Mounting

MI-WSO-PR-N Morley IAS Wall Mounted Sounder – Addressable – Red
- Manufacturer : Morley IAS by Honeywell
- Part Number : MI-WSO-PR-N
- Wall Mounted Addressable Sounder
- Colour : Red
- Requires B501AP Terminal Plate For Mounting

MI-MCP-FLEX Morley IAS Addressable Flexible Manual Call Point
Key Features:
- Unique ‘Plug & Play’ installation concept
- Re-settable operating element option
- Analogue addressable communications
- Fully compliant with EN54, Part 11
- Backward compatibility
- Enhanced aesthetics
- Integral LED
- Integral loop isolation option

MI-DMM21 Morley 2-Input Monitor Module
Fire detection and fire alarm systems installed in and around buildings


BEAMMMK System Sensor Mounting Kit
- The BEAMMMK allows reflected beam detectors and reflectors to be mounted to either a vertical wall or the ceiling. The kit allows for additional alignment range in cases where the detector and reflector cannot be mounted within 10 degree of each other. The kit includes the hardware necessary to mount either a single transmitter/receiver unit or a single reflector. (To mount the transmitter/ receiver the surface mount kit, BEAMSMK, must also be used). If the transmitter/receiver and the reflector require additional alignment range two kits are required.

MI-D240CM0 Morley Single 240 V Ac Relay Module
The MI/D240CMO addressable output module provides a single double pole contact output for 240 V AC (nominal 220 V AC) to switches the power to external equipment. The MI/D240CMO has built-in lop short circuit isolator and surface box for wall mount.

MI-WSS-PR-N Morley Intelligent Wall Mounted Sounder Strobe
Features |
|
| Model : | WSS-PR-N05 |
| Type : | Intelligent Wall Mounted Sounder Strobe |
| Mounting Type : | Wall |
| Voltage : | 15 – 32V DC |
| Color : | Red |

MI-DCZRM Morley Non-Addressable Zone Monitor Module
- Connection of a zone of non-addressable detectors to an analogue addressable fire system
- Built in isolation allowing system installation in stages without loss of protection
- Monitors open circuit and short circuit faults
- TRI-Colour Status LED
- Zone powered from addressable loop wiring or external 24V PSU
- Remote reset of non-addressable zone
- Monitoring of external power supply
- External fault input
- CPD approval to EN54-17 and EN54-18, LPCB and VdS
- DIN rail mountable, consistent with all other modules
- Support for an extended power supply range as low as 18Vdc 60mA with an External PSU

CO1224TR System Sensor Carbon Monoxide Detector
- A 10-year end-of-life timer
- RealTest® enables a functional test using canned CO
- A code-required trouble relay
- Wiring supervision with SEMS terminals
- 12/24 VDC
- A low current draw of 20 mA in standby and 40 mA in alarm
- Versatile mounting for wall and ceiling
- Accurate and reliable electrochemical sensing technology
- Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T or CO1224A.
- CO1224T tested up to 12,000 feet above sea level


W5A-RPO5SF-K013 Morley IAS Addressable Glass Weatherproof Call Point
Addressable call point for the Morley IAS protocol features Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the new WCP Outdoor Call Point range.

System Sensor D2 Duct Smoke Detector, 2-WIRe, Photoelectric
- Photoelectric, integrated low-flow technology
- Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
- Versatile mounting options in square or rectangular configuration with modular construction
- Plug-in sensor
- Superb false immunity with the latest sensor technology
- Broader ranges for operating temperature (-4ºF to 158ºF) and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- A cover tamperture to indicate a trouble condition for removed or improperly installed sensor cover
- Increased wiring space with a newly added 3/4 inch conduit knockout
- Improved LED status
- 24 V DC
- Backward compatibility with existing Innovair products, inclremote accessories

System Sensor Dnre Smoke Detector
- Photoelectric, integrated low-flow technology
- Air velocity rating from 0.5m/s to 20.32m/sec
- Versatile mounting options: square or rectangular configuration
- Broad ranges for operating temperature −20°C to 70°C and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- New Cover tamper signal
- Increased wiring space with a newly added 20mm conduit knockout
- Available space within housing to accommodate mounting of relay module
- Clear cover for convenient visual inspection

795-072-100 Morley Loop Driver Card For Morley IAS Protocol
-
Morley IAS Protocol Loop driver card for 460mA for ZX addressable fire alarm control panels.

FP200 Prysmian FIRe Resistant Cable
-
FP200 Gold is a ‘standard’ fire resistant cable as defined by fire alarm and emergency lighting British Standards and the original alternative to mineral insulated cable. It is a tough, durable and dressable essential systems cable – easy to install and terminate.

HM-PSE-S2 Morley Smoke Detector
-
Humidity 10-93 % Diameter 102 mm Color White Material ABS Height 52 mm Weight 97 g

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base

HM-RHSE Honeywell Addressable Heat Detector Hna-360-H2
-
Model HNA-360-H2 detector is advanced photoelectric smoke detection which is made with an innovative and modern design, every unit is individually tested and calibrated to ensure high reliability and prevent false alarms.
Compatible with: C-TEC, KENTEC, INIM, GLOBAL FIRE and other intelligent fire control panels.

MI-BSO-DD-N KAC Intelligent Detector Base Sounder Strobe
-
The EN54-23 Detector Base Sounder Strobe is a modular, high output loop powered device intended to alert building occupants of a potential fire.
Approved to meet EN54-23, it utilizes the System Sensor B501AP base for enhanced installation flexibility and integrates seamlessly with System Sensor intelligent detectors into a single installation point.
When triggered by the fire panel, its powerful sounder and strobe provide an audible visible warning.

MI-DMMI Morley Interface – Single Input Monitor Module
- Manufacturer : Morley by Honeywell
- Part Number : MI-DMMI
- Single Input Interface Module
- Requires M200E-SMB For Surface Mounting

MI-WSO-PR-N Morley IAS Wall Mounted Sounder – Addressable – Red
- Manufacturer : Morley IAS by Honeywell
- Part Number : MI-WSO-PR-N
- Wall Mounted Addressable Sounder
- Colour : Red
- Requires B501AP Terminal Plate For Mounting

MI-MCP-FLEX Morley IAS Addressable Flexible Manual Call Point
Key Features:
- Unique ‘Plug & Play’ installation concept
- Re-settable operating element option
- Analogue addressable communications
- Fully compliant with EN54, Part 11
- Backward compatibility
- Enhanced aesthetics
- Integral LED
- Integral loop isolation option

MI-DMM21 Morley 2-Input Monitor Module
Fire detection and fire alarm systems installed in and around buildings


BEAMMMK System Sensor Mounting Kit
- The BEAMMMK allows reflected beam detectors and reflectors to be mounted to either a vertical wall or the ceiling. The kit allows for additional alignment range in cases where the detector and reflector cannot be mounted within 10 degree of each other. The kit includes the hardware necessary to mount either a single transmitter/receiver unit or a single reflector. (To mount the transmitter/ receiver the surface mount kit, BEAMSMK, must also be used). If the transmitter/receiver and the reflector require additional alignment range two kits are required.

MI-D240CM0 Morley Single 240 V Ac Relay Module
The MI/D240CMO addressable output module provides a single double pole contact output for 240 V AC (nominal 220 V AC) to switches the power to external equipment. The MI/D240CMO has built-in lop short circuit isolator and surface box for wall mount.

MI-WSS-PR-N Morley Intelligent Wall Mounted Sounder Strobe
Features |
|
| Model : | WSS-PR-N05 |
| Type : | Intelligent Wall Mounted Sounder Strobe |
| Mounting Type : | Wall |
| Voltage : | 15 – 32V DC |
| Color : | Red |

MI-DCZRM Morley Non-Addressable Zone Monitor Module
- Connection of a zone of non-addressable detectors to an analogue addressable fire system
- Built in isolation allowing system installation in stages without loss of protection
- Monitors open circuit and short circuit faults
- TRI-Colour Status LED
- Zone powered from addressable loop wiring or external 24V PSU
- Remote reset of non-addressable zone
- Monitoring of external power supply
- External fault input
- CPD approval to EN54-17 and EN54-18, LPCB and VdS
- DIN rail mountable, consistent with all other modules
- Support for an extended power supply range as low as 18Vdc 60mA with an External PSU

CO1224TR System Sensor Carbon Monoxide Detector
- A 10-year end-of-life timer
- RealTest® enables a functional test using canned CO
- A code-required trouble relay
- Wiring supervision with SEMS terminals
- 12/24 VDC
- A low current draw of 20 mA in standby and 40 mA in alarm
- Versatile mounting for wall and ceiling
- Accurate and reliable electrochemical sensing technology
- Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T or CO1224A.
- CO1224T tested up to 12,000 feet above sea level

W5A-RPO5SF-K013 Morley IAS Addressable Glass Weatherproof Call Point
Addressable call point for the Morley IAS protocol features Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the new WCP Outdoor Call Point range.

System Sensor D2 Duct Smoke Detector, 2-WIRe, Photoelectric
- Photoelectric, integrated low-flow technology
- Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
- Versatile mounting options in square or rectangular configuration with modular construction
- Plug-in sensor
- Superb false immunity with the latest sensor technology
- Broader ranges for operating temperature (-4ºF to 158ºF) and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- A cover tamperture to indicate a trouble condition for removed or improperly installed sensor cover
- Increased wiring space with a newly added 3/4 inch conduit knockout
- Improved LED status
- 24 V DC
- Backward compatibility with existing Innovair products, inclremote accessories

System Sensor Dnre Smoke Detector
- Photoelectric, integrated low-flow technology
- Air velocity rating from 0.5m/s to 20.32m/sec
- Versatile mounting options: square or rectangular configuration
- Broad ranges for operating temperature −20°C to 70°C and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- New Cover tamper signal
- Increased wiring space with a newly added 20mm conduit knockout
- Available space within housing to accommodate mounting of relay module
- Clear cover for convenient visual inspection

795-072-100 Morley Loop Driver Card For Morley IAS Protocol
-
Morley IAS Protocol Loop driver card for 460mA for ZX addressable fire alarm control panels.

FP200 Prysmian FIRe Resistant Cable
-
FP200 Gold is a ‘standard’ fire resistant cable as defined by fire alarm and emergency lighting British Standards and the original alternative to mineral insulated cable. It is a tough, durable and dressable essential systems cable – easy to install and terminate.

HM-PSE-S2 Morley Smoke Detector
-
Humidity 10-93 % Diameter 102 mm Color White Material ABS Height 52 mm Weight 97 g

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base

HM-RHSE Honeywell Addressable Heat Detector Hna-360-H2
-
Model HNA-360-H2 detector is advanced photoelectric smoke detection which is made with an innovative and modern design, every unit is individually tested and calibrated to ensure high reliability and prevent false alarms.
Compatible with: C-TEC, KENTEC, INIM, GLOBAL FIRE and other intelligent fire control panels.

MI-BSO-DD-N KAC Intelligent Detector Base Sounder Strobe
-
The EN54-23 Detector Base Sounder Strobe is a modular, high output loop powered device intended to alert building occupants of a potential fire.
Approved to meet EN54-23, it utilizes the System Sensor B501AP base for enhanced installation flexibility and integrates seamlessly with System Sensor intelligent detectors into a single installation point.
When triggered by the fire panel, its powerful sounder and strobe provide an audible visible warning.

MI-DMMI Morley Interface – Single Input Monitor Module
- Manufacturer : Morley by Honeywell
- Part Number : MI-DMMI
- Single Input Interface Module
- Requires M200E-SMB For Surface Mounting

MI-WSO-PR-N Morley IAS Wall Mounted Sounder – Addressable – Red
- Manufacturer : Morley IAS by Honeywell
- Part Number : MI-WSO-PR-N
- Wall Mounted Addressable Sounder
- Colour : Red
- Requires B501AP Terminal Plate For Mounting

MI-MCP-FLEX Morley IAS Addressable Flexible Manual Call Point
Key Features:
- Unique ‘Plug & Play’ installation concept
- Re-settable operating element option
- Analogue addressable communications
- Fully compliant with EN54, Part 11
- Backward compatibility
- Enhanced aesthetics
- Integral LED
- Integral loop isolation option

MI-DMM21 Morley 2-Input Monitor Module
Fire detection and fire alarm systems installed in and around buildings


BEAMMMK System Sensor Mounting Kit
- The BEAMMMK allows reflected beam detectors and reflectors to be mounted to either a vertical wall or the ceiling. The kit allows for additional alignment range in cases where the detector and reflector cannot be mounted within 10 degree of each other. The kit includes the hardware necessary to mount either a single transmitter/receiver unit or a single reflector. (To mount the transmitter/ receiver the surface mount kit, BEAMSMK, must also be used). If the transmitter/receiver and the reflector require additional alignment range two kits are required.

MI-D240CM0 Morley Single 240 V Ac Relay Module
The MI/D240CMO addressable output module provides a single double pole contact output for 240 V AC (nominal 220 V AC) to switches the power to external equipment. The MI/D240CMO has built-in lop short circuit isolator and surface box for wall mount.

MI-WSS-PR-N Morley Intelligent Wall Mounted Sounder Strobe
Features |
|
| Model : | WSS-PR-N05 |
| Type : | Intelligent Wall Mounted Sounder Strobe |
| Mounting Type : | Wall |
| Voltage : | 15 – 32V DC |
| Color : | Red |

MI-DCZRM Morley Non-Addressable Zone Monitor Module
- Connection of a zone of non-addressable detectors to an analogue addressable fire system
- Built in isolation allowing system installation in stages without loss of protection
- Monitors open circuit and short circuit faults
- TRI-Colour Status LED
- Zone powered from addressable loop wiring or external 24V PSU
- Remote reset of non-addressable zone
- Monitoring of external power supply
- External fault input
- CPD approval to EN54-17 and EN54-18, LPCB and VdS
- DIN rail mountable, consistent with all other modules
- Support for an extended power supply range as low as 18Vdc 60mA with an External PSU

CO1224TR System Sensor Carbon Monoxide Detector
- A 10-year end-of-life timer
- RealTest® enables a functional test using canned CO
- A code-required trouble relay
- Wiring supervision with SEMS terminals
- 12/24 VDC
- A low current draw of 20 mA in standby and 40 mA in alarm
- Versatile mounting for wall and ceiling
- Accurate and reliable electrochemical sensing technology
- Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T or CO1224A.
- CO1224T tested up to 12,000 feet above sea level

W5A-RPO5SF-K013 Morley IAS Addressable Glass Weatherproof Call Point
Addressable call point for the Morley IAS protocol features Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the new WCP Outdoor Call Point range.

System Sensor D2 Duct Smoke Detector, 2-WIRe, Photoelectric
- Photoelectric, integrated low-flow technology
- Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
- Versatile mounting options in square or rectangular configuration with modular construction
- Plug-in sensor
- Superb false immunity with the latest sensor technology
- Broader ranges for operating temperature (-4ºF to 158ºF) and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- A cover tamperture to indicate a trouble condition for removed or improperly installed sensor cover
- Increased wiring space with a newly added 3/4 inch conduit knockout
- Improved LED status
- 24 V DC
- Backward compatibility with existing Innovair products, inclremote accessories

System Sensor Dnre Smoke Detector
- Photoelectric, integrated low-flow technology
- Air velocity rating from 0.5m/s to 20.32m/sec
- Versatile mounting options: square or rectangular configuration
- Broad ranges for operating temperature −20°C to 70°C and humidity (0% to 95% non-condensing)
- Patented sampling tube installs from front or back of the detector with no tools required
- New Cover tamper signal
- Increased wiring space with a newly added 20mm conduit knockout
- Available space within housing to accommodate mounting of relay module
- Clear cover for convenient visual inspection

795-072-100 Morley Loop Driver Card For Morley IAS Protocol
-
Morley IAS Protocol Loop driver card for 460mA for ZX addressable fire alarm control panels.

FP200 Prysmian FIRe Resistant Cable
-
FP200 Gold is a ‘standard’ fire resistant cable as defined by fire alarm and emergency lighting British Standards and the original alternative to mineral insulated cable. It is a tough, durable and dressable essential systems cable – easy to install and terminate.